Darya Tamin LogoDarya TaminMarine & Industrial Protective Coatings
Transogard Zinc Phosphate -124

Product details

Transocean

Transogard Zinc Phosphate -124

Marine alkyd primer

General description

A fast-drying alkyd primer containing zinc phosphate and other non-toxic pigments. It protects steel structures from corrosion in marine and industrial environments, can be topcoated with alkyd paints, and adheres well even to hand-tool-cleaned surfaces. Not suitable for submerged structures or for application over zinc-rich primers.

Technical data

  • Color:

Yellow (12)

Grey (56)

Ochre (66)

Volume solids: 42 –44
Density: 1.28 – 1.32 (Kg/Lit)
Gloss: Matt
Film thickness and theoretical coverage
Coat type Dry film thickness per coat (μm) Wet film thickness per coat (μm) Theoretical coverage (m²/L)
Range 40–60 95–140 10.8–7.2
Recommended 50 115 8.6
  • Application method:

Stir thoroughly before application until the paint is uniform.

  • Conventional spray:

Nozzle pressure 3 – 4 (bar)

Nozzle diameter: 1.2 – 2 (mm)

  • Airless spray:

Nozzle pressure 120 – 150 (bar)

Nozzle diameter: 0.38 – 0.53 (mm)

Spray angle: 40 – 80 °

  • :
  • Suitable; apply multiple coats as needed to achieve the required film thickness.
Thinner: T-600
Application conditions: Maximum relative humidity: 90%.

Surface temperature must be at least 3°C above the dew point. Recommended surface temperature for application: 5–35°C.

Drying and overcoating times
Surface temperature Touch dry to Hard dry Minimum overcoating interval Maximum overcoating interval
10°C 3 h 8 h 4 days 24 h Unlimited
23°C 90 min 5 h 3 days 16 h Unlimited
30°C 1 h 4 h 2 days 12 h Unlimited
40°C 30 min 2 h 1 days 8 h Unlimited

Download Technical Data Sheet

Product document or image

Frequently asked questions about Transogard Zinc Phosphate -124

What is Transogard Zinc Phosphate -124 and what is it used for?

A fast-drying alkyd primer containing zinc phosphate and other non-toxic pigments. It protects steel structures from corrosion in marine and industrial environments, can be topcoated with alkyd paints, and adheres well even to hand-tool-cleaned surfaces. Not suitable for submerged structures or for application over zinc-rich primers. For application limitations and service conditions, consult the product data sheet.

Which applications or surfaces is Transogard Zinc Phosphate -124 suitable for?

See the product categories and suitable-for classifications on this page, and confirm the final selection against project conditions and the product data sheet.

What should I check in the data sheet before application?

Check substrate preparation, compatibility with adjacent coats, application method and environmental conditions. Follow the data sheet for component ratio, film thickness and drying times.

How can I request pricing and technical information?

Use the product inquiry link on this page or contact Daryatamin. The product data sheet is the reference for technical information and application conditions.

Price inquiry

Contact Daryatamin sales for pricing on this product.

Email the sales team

Leave a comment

Your email address will not be published.